Record recurring alarms with the exact code, time, machine identity, program stage and relevant batch observations. Include what authorised response was taken and whether the event returned.
Avoid replacing the original code with a guessed diagnosis. A chronological history helps maintenance staff distinguish repeated symptoms from separate incidents and assess earlier repairs. Preserve that history when shifts change so each team does not start again with the same unsuccessful reset or incomplete description.